• Dispensing head rotates for effortless pipetting convenience • Individual piston and tip cone assembly allow for easy repair and maintenance • Compound material-made tip cone secures high sealing performance • Compatible with most universal tip brands • Online calibration is availableThe MicroPette Plus pipettes are fully autoclavable, enable easy cleaning and reduce the risk of contamination. Steam autoclaving can be performed at 121°C, 1 bar for 20 minutes. After autoclaving, the pipette must be cooled down and left to dry for 12 hours before use. It is recommended to check the performance of the pipette after each autoclaving. Greasing and sealing of the pipette piston after every 10th autoclaving will secure an enhanced function.• Pipettes cover a volume range from 0.1μL to 10mL • Ergonomic design provides excellent operating experience • Large display window allows for easy volume identification • Easy calibration and maintenance • Each MicroPette supplied with an individual calibration certificate according to ISO8655 • Online calibration is available• 8 and 12 channel pipettes are appropriate for 96 well plates • Dispensing head rotates for effortless pipetting convenience • Individual piston and tip cone assemblies allowing easy repair and maintenance • Compound material-made tip cone se-cures high sealing performance • Compatible with most universal tip brands • Online calibration is availableAll pipettes have been quality tested according to ISO8655-2:2002 and are supplied with individual calibration certificates. The quality control includes gravimetric testing of each pipette with distilled water at 22°C Our website allows users to access online calibration software and achieve accurate and timely calibration. Online calibration software is FREE to pipette users
This list is appropriate for MicroPette and MicroPette plus
(Adjustable and Fixed volume)

Volume Range

Increment

Test Volume(μl)

Accuracy error

Precision error

%

μl

%

μl

0.1-2.5μl

0.05μl

2.5

2.50%

0.0625

2.00%

0.05

1.25

3.00%

0.0375

3.00%

0.0375

0.25

12.00%

0.03

6.00%

0.015

0.5-10μl

0.1μl

10

1.00%

0.1

0.80%

0.08

5

1.50%

0.075

1.50%

0.075

1

2.50%

0.025

1.50%

0.015

2-20μl

0.5μl

20

0.90%

0.18

0.40%

0.08

10

1.20%

0.12

1.00%

0.1

2

3.00%

0.06

2.00%

0.04

5-50μl

0.5μl

50

0.60%

0.3

0.30%

0.15

25

0.90%

0.225

0.60%

0.15

5

2.00%

0.1

2.00%

0.1

10-100μl

1μl

100

0.80%

0.8

0.15%

0.15

50

1.00%

0.5

0.40%

0.2

10

3.00%

0.3

1.50%

0.15

20-200μl

1μl

200

0.60%

1.2

0.15%

0.3

100

0.80%

0.8

0.30%

0.3

20

3.00%

0.6

1.00%

0.2

50-200μl

1μl

200

0.60%

1.2

0.15%

0.3

100

0.80%

0.8

0.30%

0.3

50

1.00%

0.5

0.40%

0.2

100-1000μl

5μl

1000

0.60%

6

0.20%

2

500

0.70%

3.5

0.25%

1.25

100

2.00%

2

0.70%

0.7

200-1000μl

5μl

1000

0.60%

6

0.20%

2

500

0.70%

3.5

0.25%

1.25

200

0.90%

1.8

0.30%

0.6

1000-5000μl

50μl

5000

0.50%

25

0.15%

7.5

2500

0.60%

15

0.30%

7.5

1000

0.70%

7

0.30%

3

2-10ml

0.1ml

10ml

0.60%

60

0.20%

20

5ml

1.20%

60

0.30%

15

2ml

3.00%

60

0.60%

12

8 Chnnel adjustable volume pipette

Volume Range

Increment

Test Volume(μl)

Accuracy error

Precision error

%

μl

%

μl

0.5-10μl

0.1μl

10

1.50%

0.15

1.50%

0.15

5

2.50%

0.125

2.50%

0.125

1

4.00%

0.04

4.00%

0.04

5-50μl

0.5μl

50

1.00%

0.5

0.50%

0.25

25

1.50%

0.375

1.00%

0.25

5

3.00%

0.15

2.00%

0.1

50-300μl

5μl

300

0.70%

2.1

0.25%

0.75

150

1.00%

1.5

0.50%

0.75

50

1.50%

0.75

0.80%

0.4

12 Chnnel adjustable volume pipette

Volume Range

Increment

Test Volume(μl)

Accuracy error

Precision error

%

μl

%

μl

0.5-10μl

0.1μl

10

1.50%

0.15

1.50%

0.15

5

2.50%

0.125

2.50%

0.125

1

4.00%

0.04

4.00%

0.04

5-50μl

0.5μl

50

1.00%

0.5

0.50%

0.25

25

1.50%

0.375

1.00%

0.25

5

3.00%

0.15

2.00%

0.1

50-300μl

5μl

300

0.70%

2.1

0.25%

0.75

150

1.00%

1.5

0.50%

0.75

50

1.50%

0.75

0.80%

0.4

Volume Range

Increment

Test Volume(μl)

Accuracy error

Precision error

%

μl

%

μl

5μl

-

5μl

1.3%

0.065

1.2%

0.06

10μl

-

10μl

0.8%

0.08

0.8%

0.08

20μl

-

20μl

0.6%

0.12

0.5%

0.1

25μl

-

25μl

0.5%

0.125

0.3%

0.075

50μl

-

50μl

0.5%

0.25

0.3%

0.15

100μl

-

100μl

0.5%

0.5

0.3%

0.3

200μl

-

200μl

0.4%

0.8

0.2%

0.4

250μl

--

250μl

0.4%

1.0

0.2%

0.5

500μl

-

500μl

0.3%

1.5

0.2%

1.0

1000μl

-

1000μl

0.3%

3.0

0.2%

2.0

2000μl

-

2000μl

0.3%

6.0

0.15%

3.0

5000μl

-

5000μl

0.3%

15

0.15%

7.5

Hot Products

PCR Single Tube With Flat Cap

PCR Single Tube With Flat Cap

Multi-channel magnetic hotplate stirrer

Multi-channel magnetic hotplate stirrer

Fully Autoclavable Mechanical Single-channel adjustable pipettes

Fully Autoclavable Mechanical Single-channel adjustable pipettes

Automatic Workstation Conductive Pipette Tips

Automatic Workstation Conductive Pipette Tips

Fast Nucleic Acid testing platform, Accurate

Fast Nucleic Acid testing platform, Accurate

PCR 96 Well plate with or no skirt

PCR 96 Well plate with or no skirt

KC-48 High Flux Tissue Lyser Grinder

KC-48 High Flux Tissue Lyser Grinder

96-well deep plate with round/ square bottom & 96-well Tip comb

96-well deep plate with round/ square bottom & 96-well Tip comb

Fluorescence Quantitative PCR Detection 96 samples

Fluorescence Quantitative PCR Detection 96 samples

Vertical Laminar Flow Clean Bench (AlphaClean 1300 & OptiClean 1300)

Vertical Laminar Flow Clean Bench (AlphaClean 1300 & OptiClean 1300)

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours